Skip to product information
1 of 2

Model 6712FR Refrigerated Sampler Package (1 Polyethylene 5.5 Gallon Bottle)

Model 6712FR Refrigerated Sampler Package (1 Polyethylene 5.5 Gallon Bottle)

SKU:686710001

Regular price $ 11,020.00
Regular price Sale price $ 11,020.00
Sale Sold out

Model 6712FR Refrigerated Sampler Package.  Includes the following:

  • Model 6712FR Refrigerated Sampler.  Includes controller, refrigeration unit, distributor arm, and two pump tubes.
  • Single bottle configuration.  Includes one polyethylene 5.5 Gallon (20.5 Liter) round bottle and two discharge tubes.  Bottle includes two caps - one solid cap for transport and one with a hole to properly route the discharge tube when sampling.
  • Vinyl suction line with standard weighted polypropylene strainer (3/8 Inch I.D. x 25 ft.).  Includes tubing coupler.

Estimated Shipment Time (After Receipt of Order):  21 Day(s)

Dimensions

Model 6712FR Sampler:
Size (HxWxD): 49.3 x 26 x 26 inches (125 cm x 66 x 66 cm)
Weight (Dry): 160 lbs. (73 kg)

Specifications

--- Model 6712FR Sampler General ---
Refrigerator Body: Fiberglass reinforced plastic with UV-resistant gel coat
Power Required: 115 VAC, 60 Hz
--- Pump ---
Intake purge:​ Adjustable air purge before and after each sample.
Tubing life indicator: Provides a warning to change pump tubing.
Intake suction tubing: Vinyl or PTFE-lined; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length
Pump tubing life: Typically 1,000,000 pump counts
Maximum lift: 28 feet (8.5 m)
Repeatability: Typical ±5 ml or ±5% of the average volume in a set
Typical line velocity @ Head height: 3.0 ft./s @ 3 ft.; 2.9 ft./s @ 10 ft.; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m)
Liquid presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.
--- Controller ---
Weight: 13 lbs. (​5.9 Kg)
​Dimensions (HxWxD): 10.3 x 12.5 x 10 Inches (​26 x 31.7 x 25.4 cm)
​Operational Temperature: 32 to 120° F (​0 to 49° C)
​Enclosure Rating: NEMA 4X, 6 IP67
​Program Memory: ​Non-volatile ROM
​Flow Meter Signal Input: 5 to 15 VDC pulse or 25 ms isolated contact closure
​Number of Composite Samples: Programmable from 1 to 999 samples
​Clock Accuracy: Typically ​1 minute per month for real time clock
--- Software ---
Sample Frequency: ​1 minute to 99 hours 59 minutes (1 minute increments); non-uniform times in minutes or clock times 1 to 9,999 flow pulses
​Sampling Modes: Uniform time, non-uniform time, event, flow (flow mode is controlled by external flow meter pulses)
​Programmable Sample Volumes: ​10 to 9,990 mL (1 mL increments)
​Sample Retries: ​If no sample is detected, up to 3 attempts (user-selectable)
​Rinse Cycles: ​Automatic rinsing of suction line up to 3 rinses for each sample collection
​Program Storage: 5 sampling programs
​Sampling Stop/Resume: Up to 24 real time/date sample Stop/Resume commands

View full details